When.com Web Search

  1. Ad

    related to: power rating plate chart for electrical wire size for distance between two

Search results

  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A. Although ...

  3. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    The plate frequently contains the names of the machine and its manufacturer, so the rating plate is often called a name plate (hence the term "nameplate capacity" for a generator), although many devices carry separate nameplates and rating plates. [1] For an electric machine, the power rating is the number on its rating plate and corresponds to ...

  4. NEMA size - Wikipedia

    en.wikipedia.org/wiki/NEMA_size

    NEMA (National Electrical Manufacturers Association) contactors and motor starters are rated by sizes. These sizes are grouped by rated current and power . [ 1 ] [ 2 ]

  5. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    In the North American electrical industry, conductors thicker than 4/0 AWG are generally identified by the area in thousands of circular mils (kcmil), where 1 kcmil = 0.5067 mm 2. The next wire size thicker than 4/0 has a cross section of 250 kcmil. A circular mil is the area of a wire one mil in diameter. One million circular mils is the area ...

  6. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  7. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    For AC-operated devices (e.g. coaxial cable, loudspeakers), there may even be two power ratings, a maximum (peak) power rating and an average power rating. [5] [6] For such devices, the peak power rating usually specifies the low frequency or pulse energy, while the average power rating limits high-frequency operation. [5]

  8. IEC metric screw sized connectors - Wikipedia

    en.wikipedia.org/wiki/IEC_metric_screw_sized...

    IEC metric screw sized connectors is a family of electrical connectors defined by IEC that are named according to their ISO metric screw thread, namely M5, M8 and M12. [1] The number gives their outer screw thread diameter in millimeters as with the identically named screws.

  9. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...