When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...

  3. Balance point temperature - Wikipedia

    en.wikipedia.org/wiki/Balance_point_temperature

    The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.

  4. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    ASHRAE 55-2017 defines the Cooling Effect (CE) at elevated air speed (above 0.2 metres per second (0.66 ft/s)) as the value that, when subtracted from both the air temperature and the mean radiant temperature, yields the same SET value under still air (0.1 m/s) as in the first SET calculation under elevated air speed.

  5. Atmospheric temperature - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_temperature

    Average maximum yearly temperature is 28.7 °C and average minimum is 21.9 °C. The average temperature range is 5.7 °C only. Temperature variation throughout the year in Aracaju is very damped, with a standard deviation of 1.93 °C for the maximum temperature and 2.72 °C for the minimum temperature. [6]

  6. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    The standard suggests that the time of measurements should last two or more hours long, and it should also be a representative time of the year for this specific building. Measuring time step should be no more than five minutes for air temperature, mean radiant temperature, and humidity, and no more than three minutes for the air speed. [1]

  7. Mean radiant temperature - Wikipedia

    en.wikipedia.org/wiki/Mean_radiant_temperature

    The operative temperature, which is a more functional measure of thermal comfort in a building, is calculated from air temperature, mean radiant temperature and air speed. [6] Maintaining a balance between the operative temperature and the mean radiant temperature can create a more comfortable space. [7]

  8. Temperature anomaly - Wikipedia

    en.wikipedia.org/wiki/Temperature_anomaly

    Temperature anomaly is the difference, positive or negative, of a temperature from a base or reference value, normally chosen as an average of temperatures over a certain reference or base period. In atmospheric sciences , the average temperature is commonly calculated over a period of at least 30 years over a homogeneous geographic region, or ...

  9. Equivalent potential temperature - Wikipedia

    en.wikipedia.org/wiki/Equivalent_potential...

    So cool air lying on top of warm air can be stable, as long as the temperature decrease with height is less than the adiabatic lapse rate; the dynamically important quantity is not the temperature, but the potential temperature—the temperature the air would have if it were brought adiabatically to a reference pressure. The air around the ...

  1. Related searches unspecific vs nonspecific mean temperature relative to air temp normal setting

    atmospheric temperature rangeatmospheric temperature variation
    lowest atmospheric temperature