  1. Results From The WOW.Com Content Network
  2. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...

  3. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to form images of the organs in the body.

  4. Magnetic resonance microscopy - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_microscopy

    Magnetic field gradient: High gradient focus of magnetic resonance in a smaller volume (smaller point spread function), results in a better spatial resolution. The gradients for MRM are typically 50 to 100 times those of clinical systems. However, the construction of radio frequency (RF) coils used in MRM does not allow ultrahigh gradients.

  5. Medical imaging - Wikipedia

    en.wikipedia.org/wiki/Medical_imaging

    MRI uses three electromagnetic fields: a very strong (typically 1.5 to 3 teslas) static magnetic field to polarize the hydrogen nuclei, called the primary field; gradient fields that can be modified to vary in space and time (on the order of 1 kHz) for spatial encoding, often simply called gradients; and a spatially homogeneous radio-frequency ...

  6. Fast low angle shot magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Fast_low_angle_shot...

    For radial data sampling, the phase- and frequency-encoding gradients are replaced by two simultaneously applied frequency-encoding gradients that rotate the Fourier lines in data space. [ 1 ] [ 3 ] In either case, repetition times are as short as 2 to 10 milliseconds, so that the use of 64 to 256 repetitions results in image acquisition times ...

  7. MRI artifact - Wikipedia

    en.wikipedia.org/wiki/MRI_artifact

    Magnetic field gradients are used to spatially encode the location of signals from excited protons within the volume being imaged. The slice select gradient defines the volume (slice). Phase- and frequency-encoding gradients provide the information in the other two dimensions. Any deviation in the gradient would be represented as a distortion. [1]