Search results

  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The NEMA 14 connectors are essentially the replacements for the older NEMA 10 connectors described above, but with the addition of a dedicated grounding connection. All NEMA 14 devices offer two hots, a neutral, and a ground, allowing for both 120 and 240 V when supplied by split-phase power , or 120 and 208 V if the supply is three-phase .

  3. NEMA connectors - Wikipedia

    en.wikipedia.org/?title=NEMA_connectors&redirect=no

    This page was last edited on 15 November 2006, at 02:35 (UTC).; Text is available under the Creative Commons Attribution-ShareAlike 4.0 License; additional terms may apply.

  4. NEMA wattage label - Wikipedia

    en.wikipedia.org/wiki/NEMA_wattage_label

    NEMA wattage labels are standardized labels defined by the National Electrical Manufacturers Association (NEMA) used on street lighting fixtures to indicate the wattage of the lamp for maintenance purposes. Additionally, various colors are used to identify what type of lamp the fixture uses.

  5. Category:NEMA standards - Wikipedia

    en.wikipedia.org/wiki/Category:NEMA_standards

    NEMA connector; NEMA contact ratings; NEMA enclosure types; NEMA size This page was last edited on 3 October 2020, at 21:16 (UTC). Text is available under the ...

  6. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The pilot pin is located in the centre of main contact circle on 4- and 5-pin connectors. On 3-pin (2P+E) connectors, it is located on the contact circle opposite the ground pin. The other connectors are located 105° on either side of the earth pin, rather than 120° as in the smaller variants, to make room for the pilot pin.

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    NEMA connectors implement these requirements. The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces

  8. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Proper torque on the connectors set screws is critical to having an acceptable repair. However, use of the Alumiconn connectors is a relatively newer repair option for older aluminum wiring compared to other methods, and use of these connectors can have some of the same or similar problems with limited enclosure space as the COPALUM connectors.

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...