Search results
Results From The WOW.Com Content Network
Reversed-phase liquid chromatography (RP-LC) is a mode of liquid chromatography in which non-polar stationary phase and polar mobile phases are used for the separation of organic compounds. [ 1 ] [ 2 ] [ 3 ] The vast majority of separations and analyses using high-performance liquid chromatography (HPLC) in recent years are done using the ...
However, major drawbacks of SMB are the inability of separating a mixture into three fractions and the lack of solvent gradient applicability. In the case of antibodies, the state-of-the-art technique is based on batch affinity chromatography (with Protein A or Protein G as ligands) which is able to selectively bind antibody molecules.
Hydrophilic interaction chromatography (or hydrophilic interaction liquid chromatography, HILIC) [1] is a variant of normal phase liquid chromatography that partly overlaps with other chromatographic applications such as ion chromatography and reversed phase liquid chromatography.
A modern self-contained HPLC Schematic representation of an HPLC unit (1) solvent reservoirs, (2) solvent degasser, (3) gradient valve, (4) mixing vessel for delivery of the mobile phase, (5) high-pressure pump, (6) switching valve in "inject position", (6') switching valve in "load position", (7) sample injection loop, (8) pre-column (guard column), (9) analytical column, (10) detector (i.e ...
Fast protein liquid chromatography (FPLC), is a form of liquid chromatography that is often used to analyze or purify mixtures of proteins. As in other forms of chromatography, separation is possible because the different components of a mixture have different affinities for two materials, a moving fluid (the "mobile phase") and a porous solid ...
The effect of pH on the LCST is as follows, from a plateau value between pH 4.5 and pH 6.0, the LCST decreased up to pH 9 and below pH 4.5. This can be interpreted as requiring slightly basic or moderately acidic conditions, as the 4.5–6.0 pH region holds a maximum value of the LCST, an unfavorable condition.
Agarose-based SEC columns used for protein purification on an AKTA FPLC machine. SEC is used primarily for the analysis of large molecules such as proteins or polymers. SEC works by trapping smaller molecules in the pores of the adsorbent ("stationary phase"). This process is usually performed within a column, which typically consists of a ...
Let P and Q be two sets, each containing N points in .We want to find the transformation from Q to P.For simplicity, we will consider the three-dimensional case (=).The sets P and Q can each be represented by N × 3 matrices with the first row containing the coordinates of the first point, the second row containing the coordinates of the second point, and so on, as shown in this matrix: