Search results

  1. Results From The WOW.Com Content Network
  2. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    When modulating the actual boiler temperature lower, water temperature needs to have a low limit and be maintained above the flue gas condensation temperature for non-condensing boilers, typically above 60 °C (140 °F).

  3. Fire-tube boiler - Wikipedia

    en.wikipedia.org/wiki/Fire-tube_boiler

    By using non-condensing modulating boiler. By setting the controls (thermostats or controller with temperature sensors) with greater temperature differentials between STOP and START. At Non-Condensing Boilers make provisions so that minimum return water temperature of 130 °F (54 °C) to 150 °F (66 °C) to the boiler to avoid fireside corrosion.

  4. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    For the condensation process to work properly, the return temperature of the circulating water must be around 55 °C (131 °F) or below, so condensing boilers are often run at lower temperatures, around 70 °C (158 °F) or below, which can require larger pipes and radiators than non-condensing boilers.

  5. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Gas-fired tankless condensing boiler with hot water storage tank (US) Water typically enters residences in the US at about 10 °C (50 °F), depending on latitude and season. Hot water temperatures of 50 °C (122 °F) are usual for dish-washing, laundry and showering, which requires that the heater raise the water temperature about 40 °C (72 ...

  6. Tankless water heating - Wikipedia

    en.wikipedia.org/wiki/Tankless_water_heating

    Maintaining constant shower temperature: Similarly, unlike with a tank heater, the hot water temperature from a non-modulated tankless heater is inversely proportional to the rate of the water flow—the faster the flow, the less time the water spends in the heating element being heated. Mixing hot and cold water to the "right" temperature from ...

  7. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    The fourth category of furnace is the high-efficiency condensing gas furnace. High efficiency condensing gas furnaces typically achieve between 90% and 98% AFUE. [3] A condensing gas furnace includes a sealed combustion area, combustion draft inducer and a secondary heat exchanger. The primary gain in efficiency for a condensing gas furnace, as ...

  8. Flue-gas condensation - Wikipedia

    en.wikipedia.org/wiki/Flue-gas_condensation

    Flue gas condensation is a process, where flue gas is cooled below its water dew point and the heat released by the resulting condensation of water is recovered as low temperature heat. Cooling of the flue gas can be performed either directly with a heat exchanger or indirectly via a condensing scrubber.

  9. Boiler - Wikipedia

    en.wikipedia.org/wiki/Boiler

    A boiler is a closed vessel in which fluid (generally water) is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, [1] [page needed] [2] [page needed] including water heating, central heating, boiler-based power generation, cooking, and sanitation.