When.com Web Search

  1. Ads

    related to: electric strength test method

Search results

  1. Results From The WOW.Com Content Network
  2. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    In electrical engineering, a dielectric withstand test (also pressure test, high potential test, hipot test, or insulation test) is an electrical safety test performed on a component or product to determine the effectiveness of its insulation. The test may be between mutually insulated sections of a part, or energized parts and ground.

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.

  4. Dielectric strength - Wikipedia

    en.wikipedia.org/wiki/Dielectric_strength

    The field strength at which break down occurs is an intrinsic property of the material called its dielectric strength. In practical electric circuits electrical breakdown is often an unwanted occurrence, a failure of insulating material causing a short circuit , resulting in a catastrophic failure of the equipment.

  5. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60370 Test procedure for thermal endurance of insulating varnishes – Electric strength method IEC 60371 Specification for insulating materials based on mica IEC 60372 Locking devices for ball and socket couplings of string insulator units – Dimensions and tests

  6. Corona discharge - Wikipedia

    en.wikipedia.org/wiki/Corona_discharge

    A corona discharge occurs at locations where the strength of the electric field (potential gradient) around a conductor exceeds the dielectric strength of the air. It is often seen as a bluish glow in the air adjacent to pointed metal conductors carrying high voltages, and emits light by the same mechanism as a gas discharge lamp ...

  7. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The VLF test can be used in a number of ways: Apply VLF to cables in a simple withstand approach to detect potential failures in the cable insulation during a planned outage. The tested cable must withstand an AC voltage for a specified testing time without flashover. This method yields a "pass/fail" statement.

  8. Transformer oil testing - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil_testing

    The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil. A test voltage is applied to the electrodes and is continuously increased up to the breakdown voltage with a constant, standard-compliant slew rate of e.g. 2 kV/s.

  9. Comparative Tracking Index - Wikipedia

    en.wikipedia.org/wiki/Comparative_Tracking_Index

    The Comparative Tracking Index (CTI) is used to measure the electrical breakdown (tracking) properties of an insulating material. Tracking is an electrical breakdown on the surface of an insulating material wherein an initial exposure to electrical arcing heat carbonizes the material. The carbonized areas are more conductive than the pristine ...