When.com Web Search

  1. Ad

    related to: aci 301 specification for structural concrete construction

Search results

  1. Results From The WOW.Com Content Network
  2. American Concrete Institute - Wikipedia

    en.wikipedia.org/wiki/American_Concrete_Institute

    ACI 318 Building Code Requirements for Structural Concrete provides minimum requirements necessary to provide public health and safety for the design and construction of structural concrete buildings. [6] It is issued and maintained by the American Concrete Institute. [7] The latest edition of the code is ACI 318-19.

  3. Power trowel - Wikipedia

    en.wikipedia.org/wiki/Power_trowel

    Power trowels differ in the way they are controlled: Ride-on power trowels have two spider/rotor assemblies and are controlled by an operator sitting on a seat upon the machine, controlling the power trowel movement with two joystick/levers (these can be either mechanical or electronic/hydraulic).

  4. 50 Divisions - Wikipedia

    en.wikipedia.org/wiki/50_Divisions

    "50 Divisions" is the most widely used standard for organizing specifications and other written information for commercial and institutional building projects in the United States and Canada. [5] Standardizing the presentation of such information improves communication among all parties.

  5. 16 Divisions - Wikipedia

    en.wikipedia.org/wiki/16_Divisions

    The 16 Divisions of construction, as defined by the Construction Specifications Institute (CSI)'s MasterFormat, is the most widely used standard for organizing specifications and other written information for commercial and institutional building projects in the U.S. and Canada.

  6. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    The ACI Building Code Requirements put the following restrictions on amount of spiral reinforcement. ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in.

  7. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    The ACI 318 Building Code Requirements for Structural Concrete uses Limit State design. The ANSI/ AISC 360 Specification for Structural Steel Buildings , the ANSI/ AISI S-100 North American Specification for the Design of Cold Formed Steel Structural Members , and The Aluminum Association 's Aluminum Design Manual contain two methods of design ...

  8. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    The plate assemblies are fabricated off site, and welded together on-site to form steel walls connected by stringers. The walls become the form into which concrete is poured. Steel plate construction speeds reinforced concrete construction by cutting out the time-consuming on-site manual steps of tying rebar and building forms.

  9. Reinforced concrete structures durability - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete...

    The initiation time is related to the rate at which carbonation propagates in the concrete cover thickness.Once that carbonation reaches the steel surface, altering the local pH value of the environment, the protective thin film of oxides on the steel surface becomes instable, and corrosion initiates involving an extended portion of the steel surface.