This ability to selectively control power factor can be exploited for power factor correction of the power system to which the motor is connected. Since most power systems of any significant size have a net lagging power factor, the presence of overexcited synchronous motors moves the system's net power factor closer to unity, improving efficiency.
The minimum at unity power factor () is due to the general formula for the power P of a synchronous motor, = . In order to keep the power constant, with the line voltage at the terminals of the armature V A {\displaystyle V_{A}} also constant, any decrease in power factor has to be accommodated by a corresponding increase in the armature ...
An over-excited synchronous motor has a leading power factor. This makes it useful for power-factor correction of industrial loads. Both transformers and induction motors draw lagging (magnetising) currents from the line. On light loads, the power drawn by induction motors has a large reactive component and the power factor has a low value. The ...
Power-factor correction increases the power factor of a load, ... The reactive power drawn by the synchronous motor is a function of its field excitation.
The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator
Now, if this motor is fed with current of 2 A and assuming that back-EMF is exactly 2 V, it is rotating at 7200 rpm and the mechanical power is 4 W, and the force on rotor is = N or 0.0053 N. The torque on shaft is 0.0053 N⋅m at 2 A because of the assumed radius of the rotor (exactly 1 m).
Therefore, it is necessary to either snap the motor and connect it momentarily to a live grid or to add capacitors charged initially by residual magnetism and providing the required reactive power during operation. Similar is the operation of the induction motor in parallel with a synchronous motor serving as a power factor compensator.
The power frequency and voltage are not self regulating. The generator is able to supply current out of phase with the voltage requiring more external equipment to build a functional isolated power system. Similar is the operation of the induction motor in parallel with a synchronous motor serving as a power factor compensator.