When.com Web Search

  1. Ad

    related to: leviton tamper resistant gfci outlet wiring diagram

Search results

  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    Tamper-resistant GFCI duplex receptacle type 5-20RA, which can take 5-15 and 5-20 grounding plugs and 1-15 non-grounding plugs. These versions of the 5-15R or 5-20R receptacle are residual-current devices, and have "Test" and "Reset" buttons (and sometimes an indicator light which may be normally on or normally off per the vendor's design). In ...

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A Leviton GFCI "Decora" socket in a North American kitchen. Local electrical code requires tamper-resistant socket in homes, and requires a GFCI for socket within 1 metre of a sink. The T-slot indicates this device is rated 20 A and can take either a NEMA 5-15 or a NEMA 5-20 plug, though the latter type is rare on household appliances.

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Two-wire outlets having no grounding conductor may be protected by a GFCI or one upstream of the receptacle and must be labelled "No Equipment Ground" and "GFCI Protected". Most GFCI receptacles allow the connection and provide GFCI protection for down-stream connected receptacles.

  5. Electrical outlet tester - Wikipedia

    en.wikipedia.org/wiki/Electrical_outlet_tester

    A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...

  6. File:Leviton Dual Function AFCI GFCI Receptacle.jpg

    en.wikipedia.org/wiki/File:Leviton_Dual_Function...

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces. The 1999 Code required that new 120/240 volt ...

  8. Leviton - Wikipedia

    en.wikipedia.org/wiki/Leviton

    Leviton Manufacturing Company, Inc. is an American manufacturer of electrical wiring equipment in North America. The company produces electrical outlets including GFCI and USB charging devices , network infrastructure, lighting control systems , load centers and circuit breakers , EV charging stations, and utility submetering .

  9. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    "Switched socket-outlets and connectors with or without interlock" applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 1000 VDC or VAC and 500 Hz, and a rated current not exceeding 800 A.