When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Potentiometric surface - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_surface

    For groundwater "potentiometric surface" is a synonym of "piezometric surface" which is an imaginary surface that defines the level to which water in a confined aquifer would rise were it completely pierced with wells. [1] If the potentiometric surface lies above the ground surface, a flowing artesian well results.

  3. Aquifer test - Wikipedia

    en.wikipedia.org/wiki/Aquifer_test

    no other wells or long term changes in regional water levels (all changes in potentiometric surface are the result of the pumping well alone) Even though these assumptions are rarely all met, depending on the degree to which they are violated (e.g., if the boundaries of the aquifer are well beyond the part of the aquifer which will be tested by ...

  4. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    In fact, since the potentiometric measurement is a non-destructive measurement, assuming that the electrode is in equilibrium with the solution, we are measuring the solution's potential. Potentiometry usually uses indicator electrodes made selectively sensitive to the ion of interest, such as fluoride in fluoride selective electrodes , so that ...

  5. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    Beckman Model M pH Meter, 1937 [1] Beckman model 72 pH meter, 1960 781 pH/Ion Meter pH meter by Metrohm. A pH meter is a scientific instrument that measures the hydrogen-ion activity in water-based solutions, indicating its acidity or alkalinity expressed as pH. [2]

  6. Potentiometer - Wikipedia

    en.wikipedia.org/wiki/Potentiometer

    For touch-screen devices using resistive technology, a two-dimensional membrane potentiometer provides x and y coordinates. The top layer is thin glass spaced close to a neighboring inner layer. The underside of the top layer has a transparent conductive coating; the surface of the layer beneath it has a transparent resistive coating.

  7. Du Noüy ring method - Wikipedia

    en.wikipedia.org/wiki/Du_Noüy_ring_method

    A classical torsion wire-based du Noüy ring tensiometer. The arrow on the left points to the ring itself. The most common correction factors include Zuidema–Waters correction factors (for liquids with low interfacial tension), Huh–Mason correction factors (which cover a wider range than Zuidema–Waters), and Harkins–Jordan correction factors (more precise than Huh–Mason, while still ...

  8. Potentiometer (measuring instrument) - Wikipedia

    en.wikipedia.org/wiki/Potentiometer_(measuring...

    A metre bridge is a simple type of potentiometer which may be used in school science laboratories to demonstrate the principle of resistance measurement by potentiometric means. A resistance wire is laid along the length of a metre rule and contact with the wire is made through a galvanometer by a slider. When the galvanometer reads zero, the ...

  9. Potentiometric sensor - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_sensor

    Potentiometric solid state gas sensors have been generally classified into three broad groups. Type I sensors have an electrolyte containing mobile ions of the chemical species in the gas phase that it is monitoring. The commercial product, YSZ oxygen sensor, [1] is an example of type I.