When.com Web Search

  1. Ads

    related to: adjustable diffuser vent duct cover replacement instructions manual guide

Search results

  1. Results From The WOW.Com Content Network
  2. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  3. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space.

  4. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  5. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    For as-cataloged diffuser performance, a straight section of duct needs serve a diffuser. An elbow, or kinked flex duct, just before a diffuser often leads to poor air distribution and increased noise. Diffusers can be as a shape of round, rectangular, or can be as linear slot diffusers (LSDs).

  6. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct , chimney , VAV box , air handler , or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and ...

  7. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Round duct is made using a continuous spiral forming machine which can make round duct in nearly any diameter when using the right forming die and to any length to suit, but the most common stock sizes range evenly from 4" to 24" (10-60 cm) with 6"-12" (15-30 cm) being most commonly used. Stock pipe is usually sold in 10' (300 cm) joints.