The rating of a brushless motor is the ratio of the motor's unloaded rotational speed (measured in RPM) to the peak (not RMS) voltage on the wires connected to the coils (the back EMF). For example, an unloaded motor of K v {\displaystyle K_{\text{v}}} = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V ...
Liquid rheostats used as motor start switches, circa 1900. A liquid rheostat or water rheostat [1] or salt water rheostat is a type of variable resistor.This may be used as a dummy load or as a starting resistor for large slip ring motors.
An electric starter with sufficient power to turn a large diesel engine would itself be so large as to be impractical so there is a need for an alternative system. An air start system has three main components along with various safety components, namely the air start injector, the distributor and the air receivers.
A Dahlander motor (also known as a pole changing motor, dual- or two speed-motor) is a type of multispeed three-phase induction motor, in which the speed of the motor is varied by altering the number of poles; this is achieved by altering the wiring connections inside the motor.
Conversion of per-unit quantities to volts, ohms, or amperes requires a knowledge of the base that the per-unit quantities were referenced to. The per-unit system is used in power flow, short circuit evaluation, motor starting studies etc. The main idea of a per unit system is to absorb large differences in absolute values into base relationships.
An induction generator produces electrical power when its rotor is turned faster than the synchronous speed. For a four-pole motor (two pairs of poles on stator) powered by a 60 Hz source, the synchronous speed is 1800 rotations per minute (rpm) and 1500 RPM powered at 50 Hz. The motor always turns slightly slower than the synchronous speed.
Korndorfer starter with motor (M), autotransformer (AT) and three switches (1, 2, 3) In electrical engineering, the Korndorfer starter is a technique used for reduced voltage soft starting of induction motors. The circuit uses a three-phase autotransformer and three three-phase switches. This motor starting method has been updated and improved ...
A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...