For example, R-22 has one carbon atom, one hydrogen atom (2−1 = 1), two fluorine atoms, and one chlorine atom (4−2−1 = 1), so it is chlorodifluoromethane, while R-134 has two carbon atoms (2−1 = 1), two hydrogen atoms (3−1 = 2), four fluorine atoms, and no chlorine atoms (6−2−4 = 0), so it is one of the tetrafluoroethanes. This ...
The use of R-134a is being phased out because of its high global warming potential (GWP). HFO-1234ze(E) itself has zero ozone-depletion potential (ODP=0), a very low global warming potential (GWP < 1 ), even lower than CO 2, and it is classified by ANSI/ASHRAE [4] as class A2L refrigerant (lower flammability (see below) and lower toxicity). [5]
As a refrigerant, it is designated R-1234yf [1] and marketed under the names Opteon YF by Chemours and as Solstice YF by Honeywell. [3] R-1234yf is also a component of zeotropic refrigerant blend R-454B. HFO-1234yf has a GWP less than carbon dioxide, [4] [2] itself 1,430 times less potent than R-134a. [5]
However, like methane, R-410A has a global warming potential (GWP) that is appreciably worse than CO 2 (GWP = 1) for the time it persists. R-410A is a mixture of 50% HFC-32 and 50% HFC-125. HFC-32 has a 4.9 year lifetime and a 100-year GWP of 675 and HFC-125 has a 29-year lifetime and a 100-year GWP of 3500.
This is generally measured over a 100-year period. ODP measures the relative impact of a refrigerant to the ozone layer, standardized to R-11, which has a value of 1. [12] GWP and ODP vary greatly among the different refrigerants. CFCs are generally the highest impact, with a high GWP and ODP. HCFCs have similar GWP values and medium ODP values.
2,2-Dichloro-1,1,1-trifluoroethane or HCFC-123 is considered as an alternative to CFC-11 in low pressure refrigeration and HVAC systems, and should not be used in foam blowing processes or solvent applications.
Thanks to the low GWP value, it fulfils the requirements of EU regulation 517/2014 on refrigerants for new systems even without the certificate of exemption otherwise necessary. Systems using the refrigerant R-469A up to 3.6 kg filling quantity are exempt from the Leak test in accordance with EU regulation 517/2014.
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...