When.com Web Search

  1. Ads

    related to: copper clad aluminum wire resistance

Search results

  1. Results From The WOW.Com Content Network
  2. Copper-clad aluminium wire - Wikipedia

    en.wikipedia.org/wiki/Copper-clad_aluminium_wire

    The better conductor on the outer path causes the wire's resistance at high frequencies, where the skin effect is greater, to approach that of a pure copper wire. This improved conductivity over bare aluminum makes the copper-clad aluminium wire a good fit for radio frequency use.

  3. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  4. Copper-clad steel - Wikipedia

    en.wikipedia.org/wiki/Copper-clad_steel

    John Ferreol Monnot, metallurgist, the inventor of the first successful process for manufacturing copper-clad steel. Copper-clad steel (CCS), also known as copper-covered steel or the trademarked name Copperweld is a bi-metallic product, mainly used in the wire industry that combines the high mechanical strength of steel with the conductivity and corrosion resistance of copper.

  5. Electrical resistivities of the elements (data page) - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistivities_of...

    As quoted in an online version of: David R. Lide (ed), CRC Handbook of Chemistry and Physics, 84th Edition.CRC Press. Boca Raton, Florida, 2003; Section 4, Properties of the Elements and Inorganic Compounds; Physical Properties of the Rare Earth Metals

  6. Copper conductor - Wikipedia

    en.wikipedia.org/wiki/Copper_conductor

    An example of a copper alloy conductor is cadmium copper wire, which is used for railroad electrification in North America. [5] In Britain the BPO (later Post Office Telecommunications ) used cadmium copper aerial lines with 1% cadmium for extra strength; for local lines 40 lb/mile (1.3 mm dia) and for toll lines 70 lb/mile (1.7 mm dia).

  7. Speaker wire - Wikipedia

    en.wikipedia.org/wiki/Speaker_wire

    For aluminum or copper-clad aluminum wire, 14-gauge or heavier cable is needed to support this claim due to higher resistivity. [4] As speaker impedance drops, lower gauge (heavier) wire is needed to prevent degradation to damping factor – a measure of the amplifier's control over the position of the voice coil.