As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.
The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .
In 1934 the dual plug system was introduced with the socket rated at 15 A and three sizes of plug, fused 2 A and 5 A plugs and a 15 A plug. The 15 A "dual plug" incorporated a socket with narrower apertures than a standard Wylex 15 A socket, that accepted only the narrow rectangular pins of the lower-rated plugs. [ 27 ]
Series II current ratings are 20, 30, 60, 100, 200, 300, 350, 500 and 600 amps. The voltage ratings go up to 1000 V AC. These have been replacing the American-style for some time and are much more likely to be found in food processing, data centers, healthcare, entertainment, and other industries.
However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.
For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...
The terminal system consists of tabs (male) and receptacles (female). There are free-hanging wire and circuit board mounted versions of both tabs and receptacles. All widths come mostly in one of two tab thicknesses: 0.032 and 0.020 in (0.8 and 0.5 mm). A hand tool exists for inserting the terminals: the AMP Universal Handle. [citation needed]
The shank of the active and neutral pins of every 10 amp and 15 amp flat-pin plug sold after 3 April 2005 are required to be insulated, in accordance with AS/NZS 3112:2000. [ 1 ] Since 2000, the nominal voltage in most areas of Australia has been 230 V, [ 2 ] [ 3 ] [ 4 ] except for Western Australia, which remains at 240 V, and Queensland ...