  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.

  3. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .

  4. AC power plugs and sockets: British and related types

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets:...

    In 1934 the dual plug system was introduced with the socket rated at 15 A and three sizes of plug, fused 2 A and 5 A plugs and a 15 A plug. The 15 A "dual plug" incorporated a socket with narrower apertures than a standard Wylex 15 A socket, that accepted only the narrow rectangular pins of the lower-rated plugs. [ 27 ]

  5. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    Series II current ratings are 20, 30, 60, 100, 200, 300, 350, 500 and 600 amps. The voltage ratings go up to 1000 V AC. These have been replacing the American-style for some time and are much more likely to be found in food processing, data centers, healthcare, entertainment, and other industries.

  6. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.

  7. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  8. FASTON terminal - Wikipedia

    en.wikipedia.org/wiki/FASTON_terminal

    The terminal system consists of tabs (male) and receptacles (female). There are free-hanging wire and circuit board mounted versions of both tabs and receptacles. All widths come mostly in one of two tab thicknesses: 0.032 and 0.020 in (0.8 and 0.5 mm). A hand tool exists for inserting the terminals: the AMP Universal Handle. [citation needed]

  9. AS/NZS 3112 - Wikipedia

    en.wikipedia.org/wiki/AS/NZS_3112

    The shank of the active and neutral pins of every 10 amp and 15 amp flat-pin plug sold after 3 April 2005 are required to be insulated, in accordance with AS/NZS 3112:2000. [ 1 ] Since 2000, the nominal voltage in most areas of Australia has been 230 V, [ 2 ] [ 3 ] [ 4 ] except for Western Australia, which remains at 240 V, and Queensland ...