  2. Modbus - Wikipedia

    en.wikipedia.org/wiki/Modbus

    Exception Function code = Function code (1 byte) + 0x80. Exception Function code is equal to the Function code, except that its MSB is set to 1. Exception code (1 byte) of mb_excep_rsp_pdu is defined in the MODBUS Exception Codes table.

  3. MIL-STD-1553 - Wikipedia

    en.wikipedia.org/wiki/MIL-STD-1553

    Revision C is functionally equivalent to Revision B but contains updated graphics and tables to ease readability of the standard. [ 8 ] The MIL-STD-1553 standard is maintained by both the U.S. Department of Defense and the Aerospace branch of the Society of Automotive Engineers .

  4. List of automation protocols - Wikipedia

    en.wikipedia.org/wiki/List_of_automation_protocols

    Modbus RTU or ASCII or TCP; oBIX - Open Building Information Exchange is a standard for RESTful Web Services-based interfaces to building control systems developed by OASIS. UPB - 2-way Peer to Peer Protocol; VSCP - Very Simple Control Protocol is a free protocol with main focus on building- or home-automation; xAP – Open protocol

  5. DNP3 - Wikipedia

    en.wikipedia.org/wiki/DNP3

    Distributed Network Protocol 3 (DNP3) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies.

  6. Talk:Modbus - Wikipedia

    en.wikipedia.org/wiki/Talk:Modbus

    A total of 253 bytes for a Modbus PDU means that up to 125 registers can be read (there are no extra CRC bytes required for TCP connections). With function code 0x03 (Read Holding Registers) or 0x04 (Read Input Registers), the RESPONSE message size calculation is as follows: 253 bytes - function code (1 byte) - byte count (1 byte) = 251 data bytes

  7. Protocol converter - Wikipedia

    en.wikipedia.org/wiki/Protocol_converter

    The simplest and most commonly used conversion is protocol conversion between Modbus RTU and Modbus TCP. In this conversion, there is no change in the overall framing. Hence it is easy to take the Serial Modbus RTU frame and encapsulate it in a TCP/UDP socket and send it over Ethernet. Since both the protocol framings are the same, except for ...

  8. IEC 61131-3 - Wikipedia

    en.wikipedia.org/wiki/IEC_61131-3

    IEC 61131-3 is the third part (of 10) of the international standard IEC 61131 for programmable logic controllers.It was first published in December 1993 [1] by the IEC; the current (third) edition was published in February 2013.

  9. SAE J1939 - Wikipedia

    en.wikipedia.org/wiki/SAE_J1939

    A PGN identifies a message's function and associated data. J1939 attempts to define standard PGNs to encompass a wide range of automotive, agricultural, marine and off-road vehicle purposes. A range of PGNs (00FF00 16 through 00FFFF 16 , inclusive) is reserved for proprietary use.