When.com Web Search

  1. Ad

    related to: open circuit saturation formula calculator for water pressure

Search results

  1. Results From The WOW.Com Content Network
  2. Tetens equation - Wikipedia

    en.wikipedia.org/wiki/Tetens_equation

    The Tetens equation is an equation to calculate the saturation vapour pressure of water over liquid and ice. It is named after its creator, O. Tetens who was an early German meteorologist. It is named after its creator, O. Tetens who was an early German meteorologist.

  3. Goff–Gratch equation - Wikipedia

    en.wikipedia.org/wiki/Goff–Gratch_equation

    The saturation with respect to water cannot be measured much below –50 °C, so manufacturers should use one of the following expressions for calculating saturation vapour pressure relative to water at the lowest temperatures – Wexler (1976, 1977), [1] [2] reported by Flatau et al. (1992)., [3] Hyland and Wexler (1983) or Sonntag (1994 ...

  4. Vapour pressure of water - Wikipedia

    en.wikipedia.org/wiki/Vapour_pressure_of_water

    The boiling point of water is the temperature at which the saturated vapor pressure equals the ambient pressure. Water supercooled below its normal freezing point has a higher vapor pressure than that of ice at the same temperature and is, thus, unstable. Calculations of the (saturation) vapor pressure of water are commonly used in meteorology.

  5. Open-circuit saturation curve - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_saturation_curve

    The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve .

  6. Lee–Kesler method - Wikipedia

    en.wikipedia.org/wiki/Lee–Kesler_method

    The correct result would be P = 101.325 kPa, the normal (atmospheric) pressure. The deviation is −1.63 kPa or −1.61 %. The deviation is −1.63 kPa or −1.61 %. It is important to use the same absolute units for T and T c as well as for P and P c .

  7. Drawdown (hydrology) - Wikipedia

    en.wikipedia.org/wiki/Drawdown_(hydrology)

    Static level is the level of water in the well when no water is being removed from the well by pumping. [8] Water table is the upper level of the zone of saturation, an underground surface in which the soil or rock is permanently saturated with water. [9] Well yield is the volume of water per unit time that is produced by the well from pumping. [8]

  8. Phase diagram - Wikipedia

    en.wikipedia.org/wiki/Phase_diagram

    The pressure on a pressure-temperature diagram (such as the water phase diagram shown above) is the partial pressure of the substance in question. A phase diagram in physical chemistry , engineering , mineralogy , and materials science is a type of chart used to show conditions (pressure, temperature, etc.) at which thermodynamically distinct ...

  9. Clausius–Clapeyron relation - Wikipedia

    en.wikipedia.org/wiki/Clausius–Clapeyron_relation

    Therefore, the August–Roche–Magnus equation implies that saturation water vapor pressure changes approximately exponentially with temperature under typical atmospheric conditions, and hence the water-holding capacity of the atmosphere increases by about 7% for every 1 °C rise in temperature. [18]