When.com Web Search

  1. Ads

    related to: nitrogen pressure reducing valve

Search results

  1. Results From The WOW.Com Content Network
  2. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    They differ from pressure reducing regulators in that the pressure reducing regulator controls downstream pressure and is insensitive to upstream pressure. [2] It is a normally-closed valve which may be installed in parallel with sensitive equipment or after the sensitive equipment to provide an obstruction to flow and thereby maintain upstream ...

  3. Exhaust gas recirculation - Wikipedia

    en.wikipedia.org/wiki/Exhaust_gas_recirculation

    EGR valve the top of box on top of the inlet manifold of a Saab H engine in a 1987 Saab 90. In internal combustion engines, exhaust gas recirculation (EGR) is a nitrogen oxide (NO x) emissions reduction technique used in petrol/gasoline, diesel engines and some hydrogen engines. [1]

  4. Surge control - Wikipedia

    en.wikipedia.org/wiki/Surge_control

    These valves will remain closed until the inlet pressure exceeds the set point/nitrogen pressure, at which time the valve will open from the high pressure and remain open as long as the process pressure is above the nitrogen pressure. Once the process pressure starts to decay, the valve will start to close.

  5. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  6. Choked flow - Wikipedia

    en.wikipedia.org/wiki/Choked_flow

    For air with a heat capacity ratio =, then =; other gases have in the range 1.09 (e.g. butane) to 1.67 (monatomic gases), so the critical pressure ratio varies in the range < / <, which means that, depending on the gas, choked flow usually occurs when the downstream static pressure drops to below 0.487 to 0.587 times the absolute pressure in ...

  7. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    The pressure at which the control pilot relieves is the functional set pressure of the PORV. When the pilot valve reaches set pressure it opens and releases the pressure from the dome. The piston is then free to open and the main valve exhausts the system fluid. The control pilot opens either to the main valve exhaust pipe or to atmosphere ...