When.com Web Search

  1. Ads

    related to: grounding rod for electrical panel

Search results

  1. Results From The WOW.Com Content Network
  2. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The US National Electrical Code permitted the use of the supply neutral wire as the equipment enclosure connection to ground from 1947 to 1996 for ranges (including separate cooktops and ovens) and from 1953 to 1996 for clothes dryers, whether plug-in or permanently fixed, provided that the circuit originated in the main service panel. Normal ...

  3. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.

  4. Groundbed - Wikipedia

    en.wikipedia.org/wiki/Groundbed

    For building electrical grounding systems or earthing systems, there is a low resistance conductor bonding the metalwork and this is connected to a groundbed. The electrodes for electrical grounding are often called ground rods and are often made from steel with a copper clad surface – typically 1 to 2 m long and 20 millimetres (0.79 in) in ...

  5. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    This may lead to ground faults on variable speed drives between the drive electronics and motor not being detected for example. Disadvantages of voltage-sensing devices over current-sensing: A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices.

  7. Ufer ground - Wikipedia

    en.wikipedia.org/wiki/Ufer_Ground

    The extremely dry soil conditions would have required hundreds of feet of rods to be driven into the earth to create a low impedance ground to protect the buildings from lightning strikes. In 1942, Herbert G. Ufer was a consultant working for the U.S. Army. Ufer was given the task of finding a lower cost and more practical alternative to ...