When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  3. Feedwater heater - Wikipedia

    en.wikipedia.org/wiki/Feedwater_heater

    A Rankine cycle with two steam turbines and a single open feedwater heater. A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. [1] [2] [3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system ...

  4. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).

  5. Closed-loop controller - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_controller

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  6. Control system - Wikipedia

    en.wikipedia.org/wiki/Control_system

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  7. Heat recovery steam generator - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_steam_generator

    In this design, the inlet feedwater follows a continuous path without segmented sections for economizers, evaporators, and superheaters. This provides a high degree of flexibility as the sections are allowed to grow or contract based on the heat load being received from the gas turbine.

  8. Smith predictor - Wikipedia

    en.wikipedia.org/wiki/Smith_predictor

    However, this loop alone would not provide satisfactory control, because of the delay; this loop is feeding back outdated information. Intuitively, for the k sample intervals during which no fresh information is available, the system is controlled by the inner loop which contains a predictor of what the (unobservable) output of the plant G ...

  9. Feed forward (control) - Wikipedia

    en.wikipedia.org/wiki/Feed_forward_(control)

    In systems theory, an open system is a feed forward system that does not have any feedback loop to control its output. In contrast, a closed system uses on a feedback loop to control the operation of the system. In an open system, the output of the system is not fed back into the input to the system for control or operation. [citation needed]