Use of real time monitoring of the heart in an intensive care unit in a German hospital (2015), the monitoring screen above the patient displaying an electrocardiogram and various values of parameters of the heart like heart rate and blood pressure. Electrocardiography is the process of producing an electrocardiogram (ECG or EKG[a]), a ...
Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually the central and most visually obvious part of the tracing.
Intrinsicoid deflection. In the electrocardiogram, the intrinsicoid deflection is the downstroke of the QRS complex, from its highest amplitude until it reaches the baseline or lower. [1] Since the ventricles normally depolarize from inside to outside, this deflection reflects the depolarization vector from the endocardium to the epicardium.
Right axis deviation. The electrical axis of the heart is the net direction in which the wave of depolarization travels. It is measured using an electrocardiogram (ECG). Normally, this begins at the sinoatrial node (SA node); from here the wave of depolarisation travels down to the apex of the heart. The hexaxial reference system can be used to ...
10–20 system (EEG) The 10–20 system or International 10–20 system is an internationally recognized method to describe and apply the location of scalp electrodes in the context of an EEG exam, polysomnograph sleep study, or voluntary lab research. This method was developed to maintain standardized testing methods ensuring that a subject's ...
The current flows from the more positive subepicardium to the less positive subendocardium during phase 2 of the fast fiber type depolarization, which on ECG occurs during ST segment. The positive electrodes on the anterior chest wall detect the movement of positive charge away from the electrode and record it as a downward deflection on the ...
The Osypka TO Slim is a bipolar esophageal electrode to record filtered esophageal left heart electrograms. Osypka Rostock-Filter is a Butterworth high-pass filter. It can be used in combination with a standard ECG recorder. The output of the “Rostock filter” has to be connected to the auxiliary DC input of the electrocardiograph.
The V 5 ECG lead is placed on the anterior axillary line, horizontally even with V 4. The midaxillary line is a coronal line on the torso between the anterior and posterior axillary lines. It is a landmark used in thoracentesis , [ 2 ] and the V6 electrode of the 10 electrode ECG.