An actuated wing valve is normally used to shut in the well when flowing, thus preserving the master valves for positive shut off for maintenance purposes. Hydraulic operated wing valves are usually built to be fail safe closed, meaning they require active hydraulic pressure to stay open.
An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [ 2 ]
BTO/C – break to open/close (valve torque) BTU – British thermal units; BTU – Board of Trade Unit (1 kWh) (historical) BU – bottom up; BUL – bottom-up lag; BUR – build-up rate; BVO – ball valve operator; bwd – barrels of water per day (often used in reference to oil production) bwipd – barrels of water injected per day
Another reason relates to the hydraulic control line. Hydraulic pressure is required to keep the valve open as part of the failsafe design. However, if the valve is too far down the well, then the weight of the hydraulic fluid alone may apply sufficient pressure to keep the valve open, even with the loss of surface pressurisation.
These valves normally are set at the design pressure of the vessel. Safety relief valves serve primarily as a warning, and in most instances are too small to handle the full rated fluid capacity of the separator. Full-capacity safety relief valves can be used and are particularly recommended when no safety head (rupture disk) is used on the ...
The packer means that all the flow goes through the tubing. Within the tubing you can mount a combination of tools that will help to control fluid flow through the tubing. Gas lift well: gas is fed into valves installed in mandrels in the tubing strip. The hydrostatic head is lowered and the fluid is gas lifted to the surface.
Unlock and open, then close and relock the vent and drain valves. Unlock and open door, load pig into launcher, close and lock door. Unlock and open valves V1 and V3, to create a flow path through the launcher. Partly close ‘kicker’ valve V2 to launch the pig. The launch alarm XA will indicate when the pig has been launched. Open valve V2 ...
Gate valves are used to shut off the flow of liquids rather than for flow regulation, which is frequently done with a globe valve. When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low flow resistance. [1] The size of the open flow path generally varies in a nonlinear manner as the gate is moved.