When.com Web Search

  1. Ad

    related to: unspecific vs nonspecific mean temperature relative to air temp test for adults
    • For Warehouses

      Experts in GDP/CEIV compliance.

      Simplified monitoring procedure.

    • For Laboratories

      Automatic data logging and reports.

      Accredited calibration service.

    • For Pharma

      Fulfil GMP/GDP/CEIV compliance.

      Simplified auditing process.

    • For Biotech

      Compliance guarantee.

      Automated document generation.

Search results

  1. Results From The WOW.Com Content Network
  2. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    In design, operative temperature can be defined as the average of the mean radiant and ambient air temperatures, weighted by their respective heat transfer coefficients. [6] The instrument used for assessing environmental thermal comfort in terms of operative temperature is called a eupatheoscope and was invented by A. F. Dufton in 1929. [7]

  3. Dry-bulb temperature - Wikipedia

    en.wikipedia.org/wiki/Dry-bulb_temperature

    The dry-bulb temperature (DBT) is the temperature of air measured by a thermometer freely exposed to the air, but shielded from radiation. [1] The dry-bulb temperature is the temperature that is usually thought of as air temperature, and it is the true thermodynamic temperature. It is directly proportional to the mean kinetic energy of the air ...

  4. Wet-bulb globe temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_globe_temperature

    The wet-bulb globe temperature (WBGT) is a measure of environmental heat as it affects humans. Unlike a simple temperature measurement, WBGT accounts for all four major environmental heat factors: air temperature, humidity, radiant heat (from sunlight or sources such as furnaces), and air movement (wind or ventilation). [ 1 ]

  5. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    The standard suggests that the time of measurements should last two or more hours long, and it should also be a representative time of the year for this specific building. Measuring time step should be no more than five minutes for air temperature, mean radiant temperature, and humidity, and no more than three minutes for the air speed. [1]

  6. Apparent temperature - Wikipedia

    en.wikipedia.org/wiki/Apparent_temperature

    Apparent temperature, also known as "feels like", [1] [2] is the temperature equivalent perceived by humans, caused by the combined effects of air temperature, relative humidity and wind speed. The measure is most commonly applied to the perceived outdoor temperature.

  7. Wet-bulb temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_temperature

    The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.

  8. Heat index - Wikipedia

    en.wikipedia.org/wiki/Heat_index

    The heat index (HI) is an index that combines air temperature and relative humidity, in shaded areas, to posit a human-perceived equivalent temperature, as how hot it would feel if the humidity were some other value in the shade. For example, when the temperature is 32 °C (90 °F) with 70% relative humidity, the heat index is 41 °C (106 °F ...

  9. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    The main factors that influence thermal neutrality are those that determine heat gain and loss, namely metabolic rate, clothing insulation, air temperature, mean radiant temperature, air speed and relative humidity. Psychological parameters, such as individual expectations, and physiological parameters also affect thermal neutrality. [3]