Search results

  1. Results From The WOW.Com Content Network
  2. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  3. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  4. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The short circuit ratio (SCR) is an indicator of the strength of a network bus about the rated power of a device and is frequently used as a measure of system strength. A higher SCR value indicates a stronger system, meaning that the impact of disturbances on voltage and other variables will be minimized.

  5. Short-circuit inductance - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_inductance

    Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.

  6. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In a high resistance grounded distribution system, a feeder may develop a fault to ground but the system continues in operation. The faulted, but energized, feeder can be found with a ring-type current transformer collecting all the phase wires of the circuit; only the circuit containing a fault to ground will show a net unbalanced current. To ...

  7. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    For low-frequency applications, the power loss can be minimized by employing conductors with a large cross-sectional area, made from low-resistivity metals.With high-frequency currents, the proximity effect and skin effect cause the current to be unevenly distributed across the conductor, increasing its effective resistance, and making loss calculations more difficult.

  8. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    Circuit diagram for open-circuit test. The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of ...

  9. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Transformer in-service interruptions and failures usually result from dielectric breakdown, winding distortion caused by short circuits, hots spots caused by localized deviations in winding and electromagnetic fields, deterioration of insulation, effects of lightning and other electrical disturbances, inadequate maintenance, loose connections ...