A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A branch type AFCI trips on 75 amperes of arcing current from the line wire to either the neutral or ground wire. A combination type adds series arcing detection to branch type performance. Combination type AFCIs trip on 5 amperes of series arcing. Dual-function AFCI GFCI (ground fault circuit interrupter) 110 volt receptacle circa 2016
A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...
An automatic trip is an action performed by some system, usually a safety instrumented system, programmable logic controller, or distributed control system, to put an industrial process into a safe state. It is triggered by some parameter going into a pre-determined unsafe state.
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...
Another cause of nuisance tripping is due to accumulated or burden currents caused by items with lowered insulation resistance. This may occur due to older equipment, or equipment with heating elements, or even wiring in buildings in the tropics where prolonged damp and rain conditions can cause the insulation resistance to lower due to ...
Step 4: Alarm documentation and rationalisation (D&R) A full overhaul of the alarm system to ensure that each alarm complies with the alarm philosophy and the principles of good alarm management. Step 5: Alarm system audit and enforcement. DCS alarm systems are notoriously easy to change and generally lack proper security.
A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5] This practice has been condemned as disregarding electrical safety.