Search results
Results From The WOW.Com Content Network
Fraction of inspired oxygen (F I O 2), correctly denoted with a capital I, [1] is the molar or volumetric fraction of oxygen in the inhaled gas. Medical patients experiencing difficulty breathing are provided with oxygen-enriched air, which means a higher-than-atmospheric F I O 2.
The oxygenation index is a calculation used in intensive care medicine to measure the fraction of inspired oxygen (FiO2) and its usage within the body. A lower oxygenation index is better - this can be inferred by the equation itself. As the oxygenation of a person improves, they will be able to achieve a higher PaO2 at a lower FiO2.
The Horowitz index is defined as the ratio of partial pressure of oxygen in blood , in millimeters of mercury, and the fraction of oxygen in the inhaled air (FiO2) — the PaO 2 /FiO 2 ratio. This is calculated by dividing the PaO2 by the FiO2.
The values of SpO2 above 89% are not considered in the calculation of HTi, as such saturation levels do not contribute to the treatment. SpO2 values below 75% count as 75%. HTi is calculated as an integral value of SpO2 readings made with 1 s sampling frequency and divided by 60 in order to produce a “per minute” value.
The partial pressure of oxygen (pO 2) in the pulmonary alveoli is required to calculate both the alveolar-arterial gradient of oxygen and the amount of right-to-left cardiac shunt, which are both clinically useful quantities. However, it is not practical to take a sample of gas from the alveoli in order to directly measure the partial pressure ...
Venturi masks are used to deliver a specified fraction of inspired oxygen (F I O 2).Many masks are color-coded and have a recommended oxygen flow specified on them. [5] When used with this oxygen flow, the mask should provide the specified F I O 2.
TLC: Total lung capacity: the volume in the lungs at maximal inflation, the sum of VC and RV. TV: Tidal volume: that volume of air moved into or out of the lungs in 1 breath (TV indicates a subdivision of the lung; when tidal volume is precisely measured, as in gas exchange calculation, the symbol TV or V T is used.)
The Alveolar–arterial gradient (A-aO 2, [1] or A–a gradient), is a measure of the difference between the alveolar concentration (A) of oxygen and the arterial (a) concentration of oxygen.