When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [ 5 ] Reclosers are often used as a key component in a smart grid , as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory ...

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    The commonly available preferred values for rated current are 1 A, 2 A, 4 A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A, [6] and 125 A. The circuit breaker is labeled with the rated current in amperes prefixed by a letter, which indicates the instantaneous tripping current that causes the circuit breaker to trip ...

  6. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network.

  7. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    A fuse can clear a fault within a quarter cycle of the fault current, while a circuit breaker may take around half to one cycle to clear the fault. The response time of a fuse can be as fast as 0.002 seconds, whereas a circuit breaker typically responds in the range of 0.02 to 0.05 seconds.

  8. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).

  9. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.