A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the water heater's setpoint temperature is the most direct way to reduce scalding.
A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor temperature varies. The supply hot water temperature is modulated up and down range in an inverse linear ratio to outside air temperature. The typical range for conventional boilers is to vary the ...
The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.
Communication is digital and bi-directional between the controller (primary) and the boiler (secondary). Various commands and kinds of information can be transferred; however, the most basic command is to set the boiler's target water temperature. OpenTherm makes use of a traditional untwisted 2-wire cable between controller and boiler.
The boiler heats water to a temperature controlled by a thermostat. The water then flows (either by natural circulation or by a pump) to radiators in the rooms which are to be heated. Water also flows through a coil in the hot water tank to heat a separate mass of water for bathing, etc.
A thermostat, when set to "cool", will only turn on when the ambient temperature of the surrounding room is above the set temperature. Thus, if the controlled space has a temperature normally above the desired setting when the heating/cooling system is off, it would be wise to keep the thermostat set to "cool", despite what the temperature is ...
There are three main categories for water temperature controlling devices: Heat Source, Group Control, and Point-of-Use. Heat Source. These are used with central heating systems that use water as a medium. Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications
Maintaining constant shower temperature: Similarly, unlike with a tank heater, the hot water temperature from a non-modulated tankless heater is inversely proportional to the rate of the water flow—the faster the flow, the less time the water spends in the heating element being heated. Mixing hot and cold water to the "right" temperature from ...