When.com Web Search

  1. Ads

    related to: fire resistance rated wall requirements table by size printable

Search results

  1. Results From The WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.

  3. Building code - Wikipedia

    en.wikipedia.org/wiki/Building_code

    The hole should be firestopped to restore the fire-resistance rating of the wall. Instead, it is filled with flammable polyurethane foam . A building code (also building control or building regulations ) is a set of rules that specify the standards for construction objects such as buildings and non-building structures .

  4. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    A typical test objective for fire rated assemblies is to maintain the item or the side to be protected at or below either 140 °C (for walls, floors and electrical circuits required to have a fire-resistance rating). A typical test objective (e.g., ASTM E119) for fire rated structural protection is to limit the temperature of the structural ...

  6. List of fire-retardant materials - Wikipedia

    en.wikipedia.org/wiki/List_of_fire-retardant...

    Fire-retardant materials should not be confused with fire-resistant materials. A fire resistant material is one which is designed to resist burning and withstand heat. An example of a fire-resistant material is one which is used in bunker gear worn by firefighters to protect them from the flames of a burning building.

  7. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving evidence of functionality or fitness for purpose.

  8. Joint (building) - Wikipedia

    en.wikipedia.org/wiki/Joint_(building)

    A building joint is a junction where building elements meet without applying a static load from one element to another. When one or more of these vertical or horizontal elements that meet are required by the local building code to have a fire-resistance rating, the resulting opening that makes up the joint must be firestopped in order to restore the required compartmentalisation.

  9. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke. [1]