Zinsco would remain with copper in both their panels and breakers until the third major copper shortage in the early 1960s, when they would switch to an aluminum bus. In 1963, Zinsco introduced the R-38 twin breaker, which was the only twin circuit breaker that also made contact on both bus-bars for 240 volts in a single breaker space.
Angie's List and NBC Bay Area both highlighted an October 2002 ruling in a New Jersey Superior Court, which found that FPE (Federal Pacific Electric), the manufacturer of the Stab-Lok breakers and panels, "knowingly and purposefully [sic] distributed circuit breakers which were not tested to meet UL standards as indicated on their label". [8]
Also, larger aluminum stranded building wire made with AA-8000 series alloy of aluminum is used for electrical services (e.g. service entrance conductors from the utility connection to the service breaker panel) and for larger branch circuits such as for sub-panels, ranges, clothes dryers and air-conditioning units.
The company, in its earliest form as Federal Electric, a lighted sign company, was founded in 1901. It later made home and kitchen appliances, neon signs, police sirens, and circuit-breakers. Everything but circuit-breakers had been spun off or sold off to other companies by the 1940s, and the name was changed to Federal Pacific Electric.
A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.
Prosecutors charged an Oklahoma City police officer with felony assault on Thursday after he slammed a 71-year-old man to the ground, breaking his neck, following an argument over a traffic ticket.
Loose or poor connections in traditional electrical accessories and switchgear can cause heat to develop capable of starting a fire. This problem is known as High Resistance Connection (HRC) and safety devices such as fuses and Residual Current Devices (RCDs) are unable to disconnect the electrical supply because they cannot detect a HRC.
The 1965 edition of the NEC, article 384-15 was the first reference to the circuit total limitation of panelboards. [1] As of 2008, the location of this language is at Article 408.54 now titled "Maximum Number of Overcurrent Devices."