    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    A variation in standard temperature can result in a significant volumetric variation for the same mass flow rate. For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C).

  3. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  4. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Standard cubic feet per minute (SCFM) is a volumetric flow-rate corrected to a set of "standardized" conditions of pressure, temperature, and relative humidity. The standard conditions are often defined as 14.7 psia, temperature 70°F and relative humidity 0%, but the conditions may vary depending on the "standard" used.

  5. Standard cubic centimetres per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_centimetres...

    Standard cubic centimeters per minute (SCCM) is a unit used to quantify the flow rate of a fluid. 1 SCCM is identical to 1 cm³ STP /min. Another expression of it would be Nml/min.

  6. Standard temperature and pressure - Wikipedia

    en.wikipedia.org/wiki/Standard_temperature_and...

    Since 1982, STP has been defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of exactly 1 bar (100 kPa, 10 5 Pa). NIST uses a temperature of 20 °C (293.15 K, 68 °F) and an absolute pressure of 1 atm (14.696 psi, 101.325 kPa). [3] This standard is also called normal temperature and pressure (abbreviated as NTP).

  7. Reference atmospheric model - Wikipedia

    en.wikipedia.org/wiki/Reference_atmospheric_model

    (See graph.) Of course the real atmosphere does not have a temperature distribution with this exact shape. The temperature function is an approximation. Values for pressure and density are then calculated based on this temperature function, and the constant temperature gradients help to make some of the maths easier.

  8. PSI-Plot - Wikipedia

    en.wikipedia.org/wiki/PSI-Plot

    PSI-Plot provides various 2D and 3D plot types and allows users to customize the graphics in great detail for visual presentations and for submission to research journals for publication. Users have full control of plot and label attributes, including background color, color gradients, size, and thickness.

  9. Phase diagram - Wikipedia

    en.wikipedia.org/wiki/Phase_diagram

    It is possible to envision three-dimensional (3D) graphs showing three thermodynamic quantities. [12] [13] For example, for a single component, a 3D Cartesian coordinate type graph can show temperature (T) on one axis, pressure (p) on a second axis, and specific volume (v) on a third. Such a 3D graph is sometimes called a p–v–T diagram. The ...