Transferrin (mg/dL) = 0.7 x TIBC (μg of iron/dL) To measure TIBC in the blood is less expensive than a direct measurement of transferrin. [4] [5] The TIBC should not be confused with the unsaturated iron-binding capacity or UIBC (LOINC 2501-5, 22753-8 & 35216-1). The UIBC is calculated by subtracting the serum iron from the TIBC. [6]
Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...
Transferrin saturation (TS), measured as a percentage, is a medical laboratory value. It is the value of serum iron divided by the total iron-binding capacity [1] of the available transferrin, the main protein that binds iron in the blood, this value tells a clinician how much serum iron is bound.
Serum iron is a medical laboratory test that measures the amount of circulating iron that is bound to transferrin and freely circulate in the blood. Clinicians order this laboratory test when they are concerned about iron deficiency, which can cause anemia and other problems. 65% of the iron in the body is bound up in hemoglobin molecules in red blood cells.
Iron tests are groups of clinical chemistry laboratory blood tests that are used to evaluate body iron stores or the iron level in blood serum. Other terms used for the same tests are iron panel , iron profile , iron indices , iron status or iron studies .
MerckMedicus: total iron-binding capacity (TIBC)a measure of the total amount of iron that can be bound by the transferrin in a serum sample, determined by saturating the transferrin with iron, then removing the unbound iron with an absorbent and measuring the iron in the filtrate; used in the evaluation of patients with iron deficiency or ...
decreased total iron-binding capacity; high transferrin saturation; Hematocrit of about 20-30%; The mean corpuscular volume or MCV is usually normal or low for congenital causes of sideroblastic anemia but normal or high for acquired forms. With lead poisoning, see coarse basophilic stippling of red blood cells on peripheral blood smear
Logical Observation Identifiers Names and Codes (LOINC) is a database and universal standard for identifying medical laboratory observations. First developed in 1994, it was created and is maintained by the Regenstrief Institute , a US nonprofit medical research organization.