When.com Web Search

  1. Ad

    related to: linear diffuser size chart for water

Search results

  1. Results From The WOW.Com Content Network
  2. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    Diffusers can be as a shape of round, rectangular, or can be as linear slot diffusers (LSDs). E.g., linear slot diffusers take the form of one or several long, narrow slots, mostly semi-concealed in a fixed or suspended ceiling with airfoils behind the slots directing the airflow in the desired direction. Occasionally, diffusers are mostly used ...

  3. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Therefore, the control and optimization of this stratification is crucial to system design and sizing, energy-efficient operation, and comfort performance of UFAD systems. [ 10 ] Many factors, including the ceiling height, diffuser characteristics, number of diffusers, supply air temperature, total flow rate, cooling load and conditioning mode ...

  4. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  5. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  6. Aeration - Wikipedia

    en.wikipedia.org/wiki/Aeration

    Aeration of liquids (usually water) is achieved by: passing air through the liquid by means of the Venturi tube, aeration turbines or compressed air which can be combined with diffuser(s) air stone(s), as well as fine bubble diffusers, coarse bubble diffusers or linear aeration tubing. Ceramics are suitable for this purpose, often involving ...

  7. Fine bubble diffusers - Wikipedia

    en.wikipedia.org/wiki/Fine_bubble_diffusers

    The subject of bubble size is important because the aeration system in a wastewater or sewage treatment plant consumes an average of 50 to 70 percent of the energy of the entire plant. [3] Increasing the oxygen transfer efficiency decreases the power the plant requires to provide the same quality of effluent water.

  8. Coarse bubble diffusers - Wikipedia

    en.wikipedia.org/wiki/Coarse_bubble_diffusers

    Because of their small air openings, fine bubble diffusers cease to have an advantage. Currently, coarse bubble diffusers are the mainstay solution. These diffusers are typically made in the shape of a perforated rectangular pipe called a wide band, or a cap of 3 inches (76 mm) in diameter with an elastomeric membrane. Other varieties of coarse ...

  9. Permeation - Wikipedia

    en.wikipedia.org/wiki/Permeation

    A stack's power output depends on both the number and the size of the individual fuel cells. Thermoplastic and Thermosetting Piping: Pipes intended to transport water under high pressure can be considered as failed when there is a detectable permeation of water through the pipe wall to the outer surface of the pipe.