It requires metering for indoor, outdoor, and wastewater uses, as well as maximum flow rates for water-based heating, ventilation, and air conditioning systems. The chapter also includes requirements for water treatment systems, rainwater harvesting, greywater systems, and reclaimed water systems.
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
LEED has evolved since 1998 to more accurately represent and incorporate emerging green building technologies. LEED has developed building programs specific to new construction (NC), core and shell (CS), commercial interiors (CI), existing buildings (EB), neighborhood development (ND), homes (LEED for Homes), retail, schools, and healthcare.
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
A03 Ventilation Design topic, the WELL assured building to have existing or new mechanical ventilation systems following ASHRAE 62.1-2 or EN standard 16798-1 or AS 1668.2 or CIBSE Guide A: Environmental Design. Naturally ventilation can also be used without mechanical ventilation system if the design follows Natural Ventilation Procedure in ...
In comparison to classic displacement ventilation (DV) systems [9] that deliver air at low velocities, typical UFAD systems deliver air through floor diffusers with higher supply air velocities. In addition to increasing the amount of mixing (and therefore potentially diminishing the ventilation performance compared to DV systems), these more ...
The toughest requirements apply to large commercial buildings. Starting in November, new permit applications for high-rise residential building must submit documentation to achieve LEED certification, and that requirement ratchets up to LEED Silver in 2009 and LEED Gold in 2012.
For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...