The friction loss is customarily given as pressure loss for a given duct length, Δp / L, in units of (US) inches of water for 100 feet or (SI) kg / m 2 / s 2. For specific choices of duct material, and assuming air at standard temperature and pressure (STP), standard charts can be used to calculate the expected friction loss.
The head loss Δh (or h f) expresses the pressure loss due to friction in terms of the equivalent height of a column of the working fluid, so the pressure drop is =, where: Δh = The head loss due to pipe friction over the given length of pipe (SI units: m); [b]
Moody's team used the available data (including that of Nikuradse) to show that fluid flow in rough pipes could be described by four dimensionless quantities: Reynolds number, pressure loss coefficient, diameter ratio of the pipe and the relative roughness of the pipe.
The following table lists historical approximations to the Colebrook–White relation [23] for pressure-driven flow. Churchill equation [ 24 ] (1977) is the only equation that can be evaluated for very slow flow (Reynolds number < 1), but the Cheng (2008), [ 25 ] and Bellos et al. (2018) [ 8 ] equations also return an approximately correct ...
Process duct pressure drops (US practice) are usually measured in inches of water. A typical duct operates at about - 25 inches (160 psf.) total suction pressure, with roughly 75% of the pressure loss in the bag house, and 10% of pressure lost in duct friction, and 15% (nominal)lost in elbow turbulence.
Atkinson resistance is commonly used in mine ventilation to characterise the resistance to airflow of a duct of irregular size and shape, such as a mine roadway. It has the symbol and is used in the square law for pressure drop, =
The viscous friction causes the flow properties to change along the duct. The frictional effect is modeled as a shear stress at the wall acting on the fluid with uniform properties over any cross section of the duct. For a flow with an upstream Mach number greater than 1.0 in a sufficiently long duct, deceleration occurs and the flow can become ...
Some flexible duct markets prefer to avoid using flexible duct on the return air portions of HVAC systems, however flexible duct can tolerate moderate negative pressures. The UL181 test requires a negative pressure of 200 Pa. To use flexible ducting in a system, make sure to pull the duct tight so you get the full internal diameter.