  2. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Since the final exhaust from a condensing boiler has a lower temperature than the exhaust from an atmospheric boiler 38 °C (100 °F) vs. 204 °C (400 °F) a mechanical fan is always required to expel it, with the additional benefit of allowing the use of low-temperature exhaust piping (typically PVC in domestic applications) without insulation ...

  3. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    The supply hot water temperature is modulated up and down range in an inverse linear ratio to outside air temperature. The typical range for conventional boilers is to vary the supply water temperature from 60 to 82 °C (140 to 180 °F) as the outside temperature varies from 18 to −18 °C (64 to 0 °F).

  4. What Temperature Should You Set Your Thermostat When ... - AOL

    www.aol.com/temperature-set-thermostat-youre...

    According to the U.S. Department of Energy, you can save 10 percent on your heating bill when you change your thermostat by 7-10 degrees for just eight hours a day.

  5. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    The fourth category of furnace is the high-efficiency condensing gas furnace. High efficiency condensing gas furnaces typically achieve between 90% and 98% AFUE. [3] A condensing gas furnace includes a sealed combustion area, combustion draft inducer and a secondary heat exchanger. The primary gain in efficiency for a condensing gas furnace, as ...

  6. Condenser (heat transfer) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(heat_transfer)

    The vapor typically enters the condenser at a temperature above that of the secondary fluid. As the vapor cools, it reaches the saturation temperature, condenses into liquid, and releases large quantities of latent heat. As this process occurs along the condenser, the quantity of vapor decreases and the quantity of liquid increases; at the ...

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    For a typical late 20th-century power station, superheated steam from the boiler is delivered through 14–16-inch-diameter (360–410 mm) piping at 2,400 psi (17 MPa; 160 atm) and 1,000 °F (540 °C) to the high-pressure turbine, where it falls in pressure to 600 psi (4.1 MPa; 41 atm) and to 600 °F (320 °C) in temperature through the stage.

  8. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Heat from the space-heating boiler is transferred to the water heater vessel/container by means of a heat exchanger, and the boiler operates at a higher temperature than the potable hot water supply. Most potable water heaters in North America are completely separate from the space heating units, due to the popularity of HVAC / forced air ...

  9. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The EU standard test conditions for an air source heat pump is at dry-bulb temperature of 20 °C (68 °F) for and 7 °C (44.6 °F) for . [9] Given sub-zero European winter temperatures, real world heating performance is significantly poorer than such standard COP figures imply.