When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  3. Utilization factor - Wikipedia

    en.wikipedia.org/wiki/Utilization_factor

    The Load factor is the ratio of the load that a piece of equipment actually draws (time averaged) when it is in operation to the load it could draw (which we call full load). For example, an oversized motor - 15 kW - drives a constant 12 kW load whenever it is on. The motor load factor is then 12/15 = 80%. The motor above may only be used for ...

  4. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Depending on the load and power factor of the network, the power factor controller will switch the necessary blocks of capacitors in steps to make sure the power factor stays above a selected value. In place of a set of switched capacitors , an unloaded synchronous motor can supply reactive power.

  5. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    The motor may not reach this theoretical speed because there are non-linear mechanical losses. On the other hand, if the motor is driven as a generator, the no-load voltage between terminals is perfectly proportional to the RPM and true to the of the motor/generator.

  6. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  7. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    Under load, the speed drops and the slip increases enough to create sufficient torque to turn the load. For this reason, induction motors are sometimes referred to as "asynchronous motors". [31] An induction motor can be used as an induction generator, or it can be unrolled to form a linear induction motor which can directly generate linear ...

  8. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    Graphs by hour of California's total electric load, the total load less solar and wind power (known as the duck curve) and solar power output. Data is for October 22, 2016, a day when the wind power output was low and steady throughout the day. In electrical engineering, a load profile is a graph of the variation in the electrical load versus ...

  9. Synchronous motor - Wikipedia

    en.wikipedia.org/wiki/Synchronous_motor

    When the motor load is increased beyond the breakdown load, the motor falls out of synchronization and the rotor no longer follows the rotating magnetic field. Since the motor cannot produce torque if it falls out of synchronization, practical synchronous motors have a partial or complete squirrel-cage damper called an amortisseur winding to ...