  1. Results From The WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    Currents during such events can be several times the normal rated current. The resultant forces can distort the windings or break internal connections. For large utility-scale power transformers, high-power test laboratories have facilities to apply the very high power levels representative of a fault on an interconnected grid system.

  4. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Set of three unbalanced phasors, and the necessary symmetrical components that sum up to the resulting plot at the bottom. In 1918 Charles Legeyt Fortescue presented a paper [4] which demonstrated that any set of N unbalanced phasors (that is, any such polyphase signal) could be expressed as the sum of N symmetrical sets of balanced phasors, for values of N that are prime.

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.

  6. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  7. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  8. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  9. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.