Parasystole is a kind of arrhythmia caused by the presence and function of a secondary pacemaker in the heart, which works in parallel with the SA node. Parasystolic pacemakers are protected from depolarization by the SA node by some kind of entrance block .
A premature ventricular contraction (PVC) is a common event where the heartbeat is initiated by Purkinje fibers in the ventricles rather than by the sinoatrial node. PVCs may cause no symptoms or may be perceived as a "skipped beat" or felt as palpitations in the chest.
An ectopic beat can be further classified as either a premature ventricular contraction (PVC), or a premature atrial contraction (PAC). [1] Some patients describe this experience as a "flip" or a "jolt" in the chest, or a "heart hiccup", while others report dropped or missed beats.
A common example would be an interpolated PVC (a type of premature ventricular contraction) during normal sinus rhythm; the PVC does not cause an atrial contraction, because the retrograde impulse from the PVC does not completely penetrate the AV node. However, this AV node stimulation can cause a delay in subsequent AV conduction by modifying ...
Premature heart beats come in two different types: premature atrial contractions and premature ventricular contractions. Often they cause no symptoms but may present with fluttering in the chest or a skipped beat. They typically have no long-term complications. They most often happen naturally but may be associated with caffeine, nicotine, or ...
On the surface ECG, premature junctional contractions will appear as a normally shaped ventricular complex or QRS complex, not preceded by any atrial complex or P wave or preceded by an abnormal P wave with a shorter PR interval. Rarely, the abnormal P wave can follow the QRS.
For example, if ventricular compliance is decreased (such as in ventricular hypertrophy), the ventricle is stiffer. This results in higher ventricular end-diastolic pressures (EDP) at any given end-diastolic volume (EDV). Alternatively, for a given EDP, a less compliant ventricle would have a smaller EDV due to impaired filling.
Ashman beats are described as wide complex QRS complexes that follow a short R-R interval preceded by a long R-R interval. [3] This short QRS complex typically has a right bundle branch block morphology and represents an aberrantly conducted complex that originates above the AV node, rather than a complex that originates in either the right or left ventricle.