Results From The WOW.Com Content Network
Five definitions of the beam width are in common use: D4σ, 10/90 or 20/80 knife-edge, 1/e 2, FWHM, and D86. The beam width can be measured in units of length at a particular plane perpendicular to the beam axis, but it can also refer to the angular width, which is the angle subtended by the beam at the source.
The Gaussian function has a 1/e 2 diameter (2w as used in the text) about 1.7 times the FWHM.. At a position z along the beam (measured from the focus), the spot size parameter w is given by a hyperbolic relation: [1] = + (), where [1] = is called the Rayleigh range as further discussed below, and is the refractive index of the medium.
Neglecting divergence due to poor beam quality, the divergence of a laser beam is proportional to its wavelength and inversely proportional to the diameter of the beam at its narrowest point. For example, an ultraviolet laser that emits at a wavelength of 308 nm will have a lower divergence than an infrared laser at 808 nm, if both have the ...
The diameter of the multimode beam is then M times that of the embedded Gaussian beam everywhere, and the divergence is M times greater, but the wavefront curvature is the same. The multimode beam has M 2 times the beam area but 1/M 2 less beam intensity than the embedded beam. This holds true for any given optical system, and thus the minimum ...
Gaussian beam width () as a function of the axial distance .: beam waist; : confocal parameter; : Rayleigh length; : total angular spread In optics and especially laser science, the Rayleigh length or Rayleigh range, , is the distance along the propagation direction of a beam from the waist to the place where the area of the cross section is doubled. [1]
The wet area is the ultrasonic couplant that allows the sound to pass into the pipe wall. The method most commonly used for medical ultrasonography. Multiple probe elements produce a steerable and focused beam. [6] Focal spot size depends on probe active aperture (A), wavelength (λ) and focal length (F). [7]
In optics, the complex beam parameter is a complex number that specifies the properties of a Gaussian beam at a particular point z along the axis of the beam. It is usually denoted by q . It can be calculated from the beam's vacuum wavelength λ 0 , the radius of curvature R of the phase front , the index of refraction n ( n =1 for air), and ...
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound ...