When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power ...

  3. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    Generating units for connection to a power grid have an inherent droop speed control that allows them to share load proportional to their rating. Some generator units, especially in isolated systems, operate with isochronous frequency control, maintaining constant system frequency independent of load.

  4. Isochronous timing - Wikipedia

    en.wikipedia.org/wiki/Isochronous_timing

    A sequence of events is isochronous if the events occur regularly, or at equal time intervals. The term isochronous is used in several technical contexts, but usually refers to the primary subject maintaining a constant period or interval (the reciprocal of frequency ), despite variations in other measurable factors in the same system.

  5. Static synchronous compensator - Wikipedia

    en.wikipedia.org/wiki/Static_synchronous_compensator

    While in the slopped region between its maximums, the STATCOM is said to be in voltage regulation mode, where it either supplies capacitive vars to increase the voltage or consumes inductive vars to lower the voltage. The rate at which it does this is set by the slope, which functions similar to a generator's droop speed control. This slope is ...

  6. Automatic generation control - Wikipedia

    en.wikipedia.org/wiki/Automatic_generation_control

    In an electric power system, automatic generation control (AGC) is a system for adjusting the power output of multiple generators at different power plants, in response to changes in the load. Since a power grid requires that generation and load closely balance moment by moment, frequent adjustments to the output of generators are necessary.

  7. Governor (device) - Wikipedia

    en.wikipedia.org/wiki/Governor_(device)

    A governor, or speed limiter or controller, is a device used to measure and regulate the speed of a machine, such as an engine.. A classic example is the centrifugal governor, also known as the Watt or fly-ball governor on a reciprocating steam engine, which uses the effect of inertial force on rotating weights driven by the machine output shaft to regulate its speed by altering the input flow ...

  8. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8.

  9. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    With the SSS clutch retrofit, the existing turbine setup is largely reused. Here, the turbine uses its existing fuel source to start and sync to the grid, which is when the SSS clutch disconnects the turbine and generator. The generator thus uses grid energy to keep spinning, to provide leading or lagging reactive power as needed.