  2. Camlock (electrical) - Wikipedia

    en.wikipedia.org/wiki/Camlock_(electrical)

    Each camlock connector carries a single phase, pole, or conductor; multiple camlock connectors will be used to make a complete electrical supply or circuit. The most common form is the 16 series, rated at 400 amperes with 105 °C terminations. Also in common use is the 15 series (mini-cam), rated at 150 amperes.

  3. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The yellow P+N+E, 4h (120°) plug is a single phase connector that is in widespread use on the British Isles for 110 V building site and fairground applications. A popular model of this socket type is marketed under the brand name MK Commando [ 12 ] which leads some users to refer to all IEC 60309 sockets by the generic trademark Commando sockets .

  4. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    The maximum voltage rating of IEC 60309 connectors is 1000 V DC or AC; the maximum current rating is 800 A; and the maximum frequency 500 Hz. Plugs are available in P+N+E (unbalanced single phase with neutral), 2P+E (balanced single phase), 3P+E (3 phase without neutral), and 3P+N+E (three phase with neutral).

  5. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    Single-phase 6-50 is commonly used on farms for silo unloaders, and is used with a 6-gauge flexible power cord up to 200 ft (61 m) long. The 6-50 receptacle charges electric vehicles at the same 32- or 40-ampere maximum from charging stations , on a short cord, as the more versatile 14-50 with its fourth prong neutral not used currently for any ...

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate. For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines rated current as the maximum current that a breaker is designed to carry continuously.

  7. IEC 60038 - Wikipedia

    en.wikipedia.org/wiki/IEC_60038

    Where two voltages are given below separated by "/", the first is the root-mean-square voltage between a phase and the neutral connector, whereas the second is the corresponding root-mean-square voltage between two phases (exception: the category shown below called "One Phase", where 240 V is the root-mean-square voltage between the two legs of a split phase).