[4] The model code, IECC, and the standard, ASHRAE 90.1, apply to commercial buildings. [5] [4] [6] The IECC references several ASHRAE Standards, in particular, ASHRAE 90.1 for commercial building construction. [22] Being a part of the ICC’s collection of model codes, the IECC is revised annually and published in full-form every three years.
Air changes per hour is a measurement intended to communicate the air change effectiveness of a space’s ventilation system. Discussion around the ASHRAE standard 62, Ventilation for Acceptable Indoor Air Quality led to the development of a more direct method of measuring air change effectiveness with the use of a tracer gas. [1]
The metabolic equivalent of task (MET) is the objective measure of the ratio of the rate at which a person expends energy, relative to the mass of that person, while performing some specific physical activity compared to a reference, currently set by convention at an absolute 3.5 mL of oxygen per kg per minute, which is the energy expended when sitting quietly by a reference individual, chosen ...
ANSI/ASHRAE Standard 55 provides a table of metabolic rate of different continuous activities. These values are valid for an average adult with surface skin area of 1.8 m 2 (19.6 ft 2). The standard reminds the users that they should use their own judgment to match the activities being considered to the comparable activities in the table.
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
ASHRAE Standard 90.2: New residential buildings, and updated the standards to offer credits for roofs with high solar reflectance [10] [11] A contributing member to ASHRAE Technical Committees: TC 1.4 (Control Theory and Application), TC 1.5 (Computer Applications), TC 4.7 (Energy Calculations), TC 7.1 (Integrated Building Design), TC 7.5 ...
The 1989 ASHRAE standard (Standard 62–89) states that appropriate ventilation guidelines are 20 CFM (9.2 L/s) per person in an office building, and 15 CFM (7.1 L/s) per person for schools, while 2004 Standard 62.1-2004 has lower recommendations again (see tables below). ANSI/ASHRAE (Standard 62–89) speculated that "comfort (odor) criteria ...
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value (in K⋅m 2 /W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]