  2. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...

  3. Electrical bonding - Wikipedia

    en.wikipedia.org/wiki/Electrical_bonding

    Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.

  5. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    Bonding jumpers may be installed wherever metal parts are free to move on a hinge or bearing. This is done for electrical safety grounding, static electricity protection, and may also be useful for control of electromagnetic interference. For example, a control panel door may have a bonding jumper across the hinges so that the metal door is ...

  6. Groundbed - Wikipedia

    en.wikipedia.org/wiki/Groundbed

    For building electrical grounding systems or earthing systems, there is a low resistance conductor bonding the metalwork and this is connected to a groundbed. The electrodes for electrical grounding are often called ground rods and are often made from steel with a copper clad surface – typically 1 to 2 m long and 20 millimetres (0.79 in) in ...

  7. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The big advantage of the TT earthing system is the reduced conducted interference from other users' connected equipment. TT has always been preferable for special applications like telecommunication sites that benefit from the interference-free earthing. Also, TT systems do not pose any serious risks in the case of a broken neutral conductor.

  8. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  9. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.