Peak-to-peak amplitude (abbreviated p–p or PtP or PtoP) is the change between peak (highest amplitude value) and trough (lowest amplitude value, which can be negative). With appropriate circuitry, peak-to-peak amplitudes of electric oscillations can be measured by meters or by viewing the waveform on an oscilloscope .
Amplitude and duration contribute to the area's value. [11] Temporal Dispersion: It is the “range of conduction velocities of the fastest and slowest nerve fibers.” [11] The NCS waveform becomes wider with nerve stimulation toward the nerve's origin compared to further down the nerve, with the area under the waveform staying constant. [11]
The PAT signal is a form of pulse wave amplitude measured by incorporating both a unified pressure field and a specific isosbestic wavelength.Applying a uniform pressure field around the measured surface releases arterial wall motion restriction, magnifies the dynamic range of the recorded signal, and prevents the distention of the veins distal to the site of pressure application.
A P wave with increased amplitude can indicate hypokalemia. [3] It can also indicate right atrial enlargement. [4] A P wave with decreased amplitude can indicate hyperkalemia. [5] P-wave changes in left and right atrial hypertrophy. Bifid P waves (known as P mitrale) indicate left-atrial abnormality - e.g. dilatation [6] or hypertrophy. [1]
The definition of poor R wave progression (PRWP) varies in the literature. It may be defined, for example, as R wave of less than 2–4 mm in leads V 3 or V 4 and/or presence of a reversed R wave progression, which is defined as R in V 4 < R in V 3 or R in V 3 < R in V 2 or R in V 2 < R in V 1 , or any combination of these. [ 11 ]
Amplitude integrated electroencephalography (aEEG), cerebral function monitoring (CFM) or continuous electroencephalogram (CEEG) is a technique for monitoring brain function in intensive care settings over longer periods of time than the traditional electroencephalogram (EEG), typically hours to days.
Amplitude/Power is a setting which determines the amount of power that is driving the oscillator piston forward and backward resulting in an air volume (tidal volume) displacement. The effect of the amplitude on the ΔP that it is changed by the displacement of the oscillator piston and hence the oscillatory pressure (ΔP).
The T wave can be described by its symmetry, skewness, slope of ascending and descending limbs, amplitude and subintervals like the T peak –T end interval. [1] In most leads, the T wave is positive. This is due to the repolarization of the membrane. During ventricle contraction (QRS complex), the heart depolarizes.