Results From The WOW.Com Content Network
Blood is drawn into a test tube containing liquid sodium citrate, which acts as an anticoagulant by binding the calcium in a sample. The blood is mixed, then centrifuged to separate blood cells from plasma (as prothrombin time is most commonly measured using blood plasma). In newborns, a capillary whole blood specimen is used. [2]
Gas chromatography–mass spectrometry (GC–MS) is an analytical method that combines the features of gas-chromatography and mass spectrometry to identify different substances within a test sample. [1] Applications of GC–MS include drug detection, fire investigation, environmental analysis, explosives investigation, food and flavor analysis ...
The use of trapezoidal rule in AUC calculation was known in literature by no later than 1975, in J.G. Wagner's Fundamentals of Clinical Pharmacokinetics. A 1977 article compares the "classical" trapezoidal method to a number of methods that take into account the typical shape of the concentration plot, caused by first-order kinetics. [8]
EMIT therapeutic drug monitoring tests provide accurate information about the concentration of such drugs such as immunosuppressant drugs and some antibiotics. [ 3 ] [ 4 ] EMIT urine assays for drugs such as cannabinoids, morphine, and amphetamine are designed to detect the drug itself or a metabolite of the drug present in a concentration ...
GC content is found to be variable with different organisms, the process of which is envisaged to be contributed to by variation in selection, mutational bias, and biased recombination-associated DNA repair. [19] The average GC-content in human genomes ranges from 35% to 60% across 100-Kb fragments, with a mean of 41%. [20]
A thrombin generation assay (TGA) or thrombin generation test (TGT) is a global coagulation assay (GCA) and type of coagulation test which can be used to assess coagulation and thrombotic risk. [ 1 ] [ 2 ] [ 3 ] It is based on the potential of a plasma to generate thrombin over time, following activation of coagulation via addition of ...
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
A high throughput assay can be either an endpoint or a kinetic assay usually done on an automated platform in 96-, 384- or 1536-well microplate formats (High Throughput Screening). Such assays are able to test large number of compounds or analytes or make functional biological readouts in response to a stimuli and/or compounds being tested. [6]