The first step in planning a substation layout is the preparation of a one-line diagram, which shows in simplified form the switching and protection arrangement required, as well as the incoming supply lines and outgoing feeders or transmission lines. It is a usual practice by many electrical utilities to prepare one-line diagrams with ...
Most of the world uses 50 Hz 220 or 230 V single phase, or 400 V three-phase for residential and light industrial services. In this system, the primary distribution network supplies a few substations per area, and the 230 V / 400 V power from each substation is directly distributed to end users over a region of normally less than 1 km radius.
An HVDC converter station (or simply converter station) is a specialised type of substation which forms the terminal equipment for a high-voltage direct current (HVDC) transmission line. [1] It converts direct current to alternating current or the reverse. In addition to the converter, the station usually contains:
A circuit diagram (or: wiring diagram, electrical diagram, elementary diagram, electronic schematic) is a graphical representation of an electrical circuit. A pictorial circuit diagram uses simple images of components, while a schematic diagram shows the components and interconnections of the circuit using standardized symbolic representations.
Schematic Diagram of the New Lots substation. Like the New Haven, the NYCR traction power was distributed using the 2 x 11 kV autotransformer topology. Two wires, the feeder and the catenary (often called the trolley wire), carried voltage of 11 kV to ground, but of opposite phase such that the feeder and catenary were 22 kV phase-to-phase.
The switching stations contain three autotransformers similar to the paralleling stations (which have one), and also have additional circuit breakers to allow segmentation of catenary and cross-connection between power zones. Electrical sections encompass both tracks between a substation and the adjacent switching stations.
These substations may consist of two to eight or more primary transformers connected to the same secondary bus to provide reliable facility power. Examples of such single facilities include airports, hospitals , major data processing centers (especially those using uninterruptible power supplies ), and sports arenas that regularly broadcast ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...