Search results
Results From The WOW.Com Content Network
The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n
NFRC labels provide performance ratings for such products in five categories: U-value, Solar Heat Gain Coefficient, Visible Transmittance, Air Leakage, and Condensation Resistance. [1] This allows architects, builders, code officials, contractors, home owners, and specifiers to compare the energy efficiency among products, and determine whether ...
All VCP manufactured in the U.S. must comply with ASTM C425 to provide a flexible leak-free joint. Clay pipe has been in-use in sanitary sewer systems for at least 5,000 years [ 3 ] Production
The American Public Works Association publication, Special Report #62, describes the use and value of facility condition rating systems in Chapter 3.6. Within the US Federal Government, the "condition index" (CI) is a general measure of the constructed asset's condition at a specific point in time. [ 2 ]
Floor Area ratio is sometimes called floor space ratio (FSR), floor space index (FSI), site ratio or plot ratio. The difference between FAR and FSI is that the first is a ratio, while the latter is an index. Index numbers are values expressed as a percentage of a single base figure. Thus an FAR of 1.5 is translated as an FSI of 150%.
Leakage area estimates can also be normalized for the size of the enclosure being tested, For example, the LEED Green Building Rating System has set an airtightness standard for multi-family dwelling units of 1.25 square inches (8.1 cm 2) of leakage area per 100 square feet (9.3 m 2) of enclosure area, to control tobacco smoke between units.
A03 Ventilation Design topic, the WELL assured building to have existing or new mechanical ventilation systems following ASHRAE 62.1-2 or EN standard 16798-1 or AS 1668.2 or CIBSE Guide A: Environmental Design. Naturally ventilation can also be used without mechanical ventilation system if the design follows Natural Ventilation Procedure in ...
Pendulum floor slip resistance tester. The ASTM E303-22 [1] (United States), BS EN 16165:2021, [2] BS EN 13036-4:2011 [3] (United Kingdom and many other European nations), AS 4663:2013 - Slip resistance of existing pedestrian surfaces, and AS 4586:2013 - Slip resistance classification of new pedestrian surface materials (Australia/New Zealand) slip resistance test standards define the pendulum ...