The ASME B16 Standardization of Valves Flanges, Fittings and Gaskets Committee, which operates under ASME’s Board on Pressure Technology Codes and Standards is responsible for standards covering valves, flanges, pipe fittings, gaskets and valve actuators for use in pressure services.
It is theoretically possible that, when both valves are faulty, backflow could occur, should the reverse flow rate exceed the capacity of the relief valve. Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become ...
Pipe rams close around a drill pipe, restricting flow in the annulus (ring-shaped space between concentric objects) between the outside of the drill pipe and the wellbore, but do not obstruct flow within the drill pipe. Variable-bore pipe rams can accommodate tubing in a wider range of outside diameters than standard pipe rams, but typically ...
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.
A threaded pipe has a screw thread at one or both ends for assembly. Steel pipe is often joined with threaded connections; tapered threads are cut into the end of the pipe, and sealant is applied in the form of thread-sealing compound or thread seal tape (also known as PTFE or Teflon tape) and the pipe is screwed into a threaded fitting with a ...
A safety valve is a valve that acts as a fail-safe. An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits. Pilot-operated relief valves are a specialized type of pressure safety valve.
The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...
λ D = The dangerous failure rate of the safety function. TI FC = The full closure interval, i.e. how often the valve must be full closed for testing. TI PST = The partial stroke test interval. The proof test coverage is a measure of how effective the partial stroke test is and the higher the PTC the greater the effect of the test.